{"id":1298,"date":"2026-03-04T20:23:52","date_gmt":"2026-03-04T20:23:52","guid":{"rendered":"https:\/\/sadiquemanifestation.com\/index.php\/product\/shahig-compass-ax12-remote-monitoring-system-for-mv-fault-indicators\/"},"modified":"2026-03-04T20:27:41","modified_gmt":"2026-03-04T20:27:41","slug":"shahig-compass-ax12-remote-monitoring-system-for-mv-fault-indicators","status":"publish","type":"product","link":"https:\/\/shahig.com\/index.php\/product\/shahig-compass-ax12-remote-monitoring-system-for-mv-fault-indicators\/","title":{"rendered":"ComPass AX12"},"content":{"rendered":"<h3>Overview<\/h3>\n<p><b>Shahig ComPass AX12<\/b> is a compact remote monitoring solution for MV applications. It combines short-circuit and earth-fault indication with an integrated RTU to transmit alarms and measured values to the control center\/SCADA for faster fault location and improved network reliability.<\/p>\n<h3>Key Features<\/h3>\n<ul>\n<li>Short-circuit and earth-fault indication using <b>only 3 single-phase current sensors<\/b><\/li>\n<li>Continuous phase-selective current monitoring<\/li>\n<li>Integrated RTU with cellular communication (GSM\/GPRS)<\/li>\n<li>Retrofittable: easy and quick installation in existing MV stations<\/li>\n<li>System includes concentrator + mini\u2011SCADA for centralized monitoring (configuration dependent)<\/li>\n<li>Utility protocol readiness: IEC\u2011104 and DNP3 ready (project dependent)<\/li>\n<li>Web-hosted remote monitoring with optional e\u2011mail \/ SMS notifications<\/li>\n<\/ul>\n<h3>Technical Data<\/h3>\n<ul>\n<li><b>Applicable neutral earthing:<\/b> solidly grounded \/ low impedance<\/li>\n<li><b>Short-circuit trip current (I&gt;&gt;):<\/b> 10\u20132,000 A<\/li>\n<li><b>Short-circuit response delay:<\/b> 40 ms \u2013 60 s<\/li>\n<li><b>Earth fault trip current (IE&gt;):<\/b> 20\u20131,000 A<\/li>\n<li><b>Earth fault response delay:<\/b> 40 ms \u2013 60 s<\/li>\n<li><b>Measured values:<\/b> phase currents (L1\/L2\/L3), IE with phase angles<\/li>\n<li><b>Accuracy:<\/b> 3% (0\u2013630 A, resolution 1 A); 5% (630\u20131,500 A); 10% (1,500\u20132,000 A)<\/li>\n<li><b>Event history:<\/b> local event log + unlimited via web-hosted application (configuration dependent)<\/li>\n<\/ul>\n<h3>Communication &amp; Remote Monitoring<\/h3>\n<ul>\n<li>GSM\/GPRS communication (SIM card provided by customer) or centralized data concentrator (project dependent)<\/li>\n<li>Status monitoring: signal strength, communication status, station status<\/li>\n<li>Data export and web access (configuration dependent)<\/li>\n<\/ul>\n<h3>Web Application Functions (Configuration Dependent)<\/h3>\n<ul>\n<li>Network overview\/dashboard (mimic)<\/li>\n<li>GIS \/ mapping and GPS location support<\/li>\n<li>Warnings and alarms display<\/li>\n<li>E\u2011mail and SMS notification management<\/li>\n<li>Threshold settings for analog data<\/li>\n<li>Trend graphs and downloadable data tables<\/li>\n<\/ul>\n<h3>Power Supply &amp; Housing<\/h3>\n<ul>\n<li><b>Mains supply:<\/b> 115 or 230 VAC (\u00b110%), 50\/60 Hz (selectable)<\/li>\n<li><b>Back-up battery:<\/b> &gt;48 hours<\/li>\n<li><b>Housing:<\/b> fiberglass reinforced polyester<\/li>\n<li><b>Ingress protection:<\/b> IP66<\/li>\n<li><b>Dimensions:<\/b> 400 \u00d7 300 \u00d7 200 mm<\/li>\n<li><b>Split-core cable-type current sensors:<\/b> conductor \u00d8 15\u201360 mm<\/li>\n<li><b>Temperature range:<\/b> \u221225 to +85 \u00b0C<\/li>\n<\/ul>\n<h3>Integrated Components<\/h3>\n<ul>\n<li>Remote monitoring unit with OLED indication<\/li>\n<li>Integrated RTU for remote reporting<\/li>\n<li>3 \u00d7 split-core current sensors (single-phase)<\/li>\n<li>Optional: data concentrator \/ mini\u2011SCADA and web-hosted platform access<\/li>\n<\/ul>\n<h3>Compliance &amp; Standards<\/h3>\n<ul>\n<li>Utility-grade MV monitoring and fault indication solution<\/li>\n<li>Protocol readiness: IEC\u2011104 \/ DNP3 (project dependent)<\/li>\n<li>Ingress protection: IP66<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p><strong>ComPass AX12 \u2013 Remote Monitoring System for MV Fault Indicators<\/strong><br \/>\nCompact MV remote monitoring system combining short-circuit &amp; earth-fault indication with integrated RTU, continuous current monitoring, GSM\/GPRS communication and web-hosted monitoring (configuration dependent).<\/p>\n","protected":false},"featured_media":1300,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[],"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[157,137,24,127],"product_tag":[163,112,118,161,162,160,139,81,123,130,113],"class_list":["post-1298","product","type-product","status-publish","has-post-thumbnail","product_cat-compass","product_cat-network-protection-systems","product_cat-power-utility-sector","product_cat-smart-fault-indicators-for-electrical-networks","product_tag-dnp3","product_tag-earth-fault","product_tag-fault-indicator","product_tag-gsm-gprs","product_tag-iec-104","product_tag-mv-applications","product_tag-network-protection","product_tag-remote-monitoring","product_tag-scada","product_tag-shahig","product_tag-short-circuit","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/product\/1298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/comments?post=1298"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/media\/1300"}],"wp:attachment":[{"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/media?parent=1298"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=1298"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1298"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shahig.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1298"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}