Overview
Shahig ComPass AX12 is a compact remote monitoring solution for MV applications. It combines short-circuit and earth-fault indication with an integrated RTU to transmit alarms and measured values to the control center/SCADA for faster fault location and improved network reliability.
Key Features
- Short-circuit and earth-fault indication using only 3 single-phase current sensors
- Continuous phase-selective current monitoring
- Integrated RTU with cellular communication (GSM/GPRS)
- Retrofittable: easy and quick installation in existing MV stations
- System includes concentrator + mini‑SCADA for centralized monitoring (configuration dependent)
- Utility protocol readiness: IEC‑104 and DNP3 ready (project dependent)
- Web-hosted remote monitoring with optional e‑mail / SMS notifications
Technical Data
- Applicable neutral earthing: solidly grounded / low impedance
- Short-circuit trip current (I>>): 10–2,000 A
- Short-circuit response delay: 40 ms – 60 s
- Earth fault trip current (IE>): 20–1,000 A
- Earth fault response delay: 40 ms – 60 s
- Measured values: phase currents (L1/L2/L3), IE with phase angles
- Accuracy: 3% (0–630 A, resolution 1 A); 5% (630–1,500 A); 10% (1,500–2,000 A)
- Event history: local event log + unlimited via web-hosted application (configuration dependent)
Communication & Remote Monitoring
- GSM/GPRS communication (SIM card provided by customer) or centralized data concentrator (project dependent)
- Status monitoring: signal strength, communication status, station status
- Data export and web access (configuration dependent)
Web Application Functions (Configuration Dependent)
- Network overview/dashboard (mimic)
- GIS / mapping and GPS location support
- Warnings and alarms display
- E‑mail and SMS notification management
- Threshold settings for analog data
- Trend graphs and downloadable data tables
Power Supply & Housing
- Mains supply: 115 or 230 VAC (±10%), 50/60 Hz (selectable)
- Back-up battery: >48 hours
- Housing: fiberglass reinforced polyester
- Ingress protection: IP66
- Dimensions: 400 × 300 × 200 mm
- Split-core cable-type current sensors: conductor Ø 15–60 mm
- Temperature range: −25 to +85 °C
Integrated Components
- Remote monitoring unit with OLED indication
- Integrated RTU for remote reporting
- 3 × split-core current sensors (single-phase)
- Optional: data concentrator / mini‑SCADA and web-hosted platform access
Compliance & Standards
- Utility-grade MV monitoring and fault indication solution
- Protocol readiness: IEC‑104 / DNP3 (project dependent)
- Ingress protection: IP66